Installation Instructions HI-4000 - HI-4001 Bidets

Getting Started

(Read all instructions before you begin)

(Click Graphics to Enlarge)

Follow these steps:
  • If you lack electrical or plumbing experience you should have a professional install the bidet.
  • Unpack the bidet
  • Tools Required: Pliers, Wrench, and Straight Slot Screwdriver

Caution:

  • The operational water pressure range required is between 12-100 Pound Per Square Inch (PSI). If the pressure is low the water stream pressure of the shower will be affected.
  • Do not turn on the water or power until installation is complete.
Step 1: Loosen the nuts on the mounting bolts and remove the toilet seat assembly.
Step 2: First, insert black rectangular rubber pad under white slide plate (Base B). Next, place two bolts through Base B then through flat, grey rubber washer. Insert bolt into seat mounting hole and fasten with cone shaped grey rubber washer and nuts.
Step 3: Push the bidet system onto slide plate following the arrow. When secure a click will sound.
To Uninstall: push seat release button and slide off the bidet unit.
Step 4: Shut off water supply valve (located at the bottom of the wall). Flush the toilet to empty water tank. Remove the water hose from the bottom of the water tank (Ball Cock).
Step 5: Attach T connector (provided) to the bottom of the water tank. Teflon tape is not required for installation. Keep all connections aligned and do not over tighten, as this may damage connections.
Step 6: Connect water hose to T connector (7/8" threaded side).
Step 7: Connect Flexible water hose (provided) from T connector (1/2" threaded side) to system external water tank located under the control panel.
Trial Operations After you have completed the above steps it is time to test the operation of the bidet.
Completed Installation

Note: The Bidet System will automatically shut off after 5 minutes of use. Press "Bidet On", "Wash On", or "Dryer" button to continue use.

1. Action:
  • Open on the shutoff valve and check for water leaks.
  • Control Panel lights will turn on when system is plugged in.
2. Action:
  • Maintain pressure near the junction of the lid and seat to operate the following trial.
Trail Operation
  • Click the graphic to review the testing procedure.
  • Open the water shut off valve and plug in unit.
  • Press the "{Wash" or "Bidet" button while pressing down right side of the seat for about 45 seconds.
  • Water has filled lines and tank when the nozzle start to extend.
  • The dryer function will stop automatically after 5 minutes.

Washing and Adjusting functions

(Click graphic for Instructions)